New Orleans Department of Safety & Permits

New Orleans, LA

Avg Review

35d

Rejection Rate

55%

Skill Files

8

Status

High Risk

Ventilation — New Orleans Type I Hood

2018 IMC w/ LA amendments / NFPA 96
ventilation
42% rejection

Type I hoods per IMC with Louisiana amendments. Exhaust 400 CFM/LF. Makeup air required. Hot/humid climate — dehumidification critical. Rooftop equipment must be hurricane-rated.

Examiner Note: NOLA Safety & Permits follows LA amendments. Hurricane-rated equipment required. Show product approvals for rooftop equipment.

Common rejection: Rooftop equipment not hurricane-rated; makeup air dehumidification not specified

Correction: Show hurricane-rated product approvals for rooftop equipment. Specify dehumidified makeup air. Include exhaust CFM on M-1.

Fire Suppression — New Orleans NFPA 96

NFPA 96 / UL 300 / NOFD Fire Prevention
fire

UL 300 suppression for Type I hoods. New Orleans Fire Department reviews fire plans. Automatic gas shutoff. Manual pull station.

Examiner Note: NOFD reviews fire plans as part of Safety & Permits process. Include fire details in submittal.

Common rejection: UL 300 documents missing; fire suppression plan incomplete

Correction: Include UL 300 documents. Show suppression system, gas shutoff on FP-1.

Plumbing — New Orleans Grease Interceptor

2018 IPC w/ LA amendments / SWBNO
plumbing

Grease interceptor per IPC with LA amendments. Sewerage & Water Board of New Orleans (SWBNO) reviews FOG. 3-comp sink. SWBNO has specific grease management requirements.

Examiner Note: SWBNO reviews interceptor and may have additional requirements beyond IPC. Submit to SWBNO early.

Common rejection: SWBNO review not initiated; interceptor not meeting SWBNO requirements

Correction: Submit interceptor to SWBNO. Show sizing per IPC/LA amendments on P-1. Comply with SWBNO FOG requirements.

Electrical — New Orleans Kitchen Circuits

2017 NEC w/ LA amendments
electrical

NEC with LA amendments. GFCI within 6 feet of water. Emergency disconnect. LA electrical license required. Flood zone electrical requirements.

Examiner Note: NOLA requires flood zone electrical considerations. Electrical panels above BFE. LA electrical license on application.

Common rejection: Electrical panel below BFE in flood zone; LA electrical license not on application

Correction: Verify flood zone and place electrical panels above BFE. Include LA electrical license. Add GFCI on E-1.

Health — New Orleans Food Facility

LA RS 40:4 / LA DHHS / NOLA Health Dept
health

Louisiana DHHS and NOLA Health Department review food facility plans. Handwash, 3-comp sink, FRP, sealed floors. Separate health permit required.

Examiner Note: NOLA Health requires separate plan review. Submit early due to potentially slow processing.

Common rejection: Health department review not submitted; food facility requirements not met

Correction: Submit food facility plan to NOLA Health Department per LA RS 40:4. Specify all finishes and fixtures.

Structural — New Orleans Flood & Hurricane Design

2018 IBC w/ LA amendments / ASCE 7-16 / ASCE 24
structural
48% rejection

Seismic Design Category A. BUT wind speed 140-150 mph (hurricane zone). Most of NOLA in Special Flood Hazard Area (SFHA). Building must comply with ASCE 24 flood design. Elevated construction may be required. LA PE required.

Examiner Note: NOLA Safety & Permits strictly enforces flood zone requirements. Verify FEMA flood zone, BFE, and ASCE 24 compliance. This is the #1 structural issue in NOLA.

Common rejection: Flood zone/BFE not addressed; ASCE 24 compliance not shown; wind loads for hurricane incomplete

Correction: Provide LA PE-stamped calculations with ASCE 24 flood design and hurricane wind loads. Show BFE compliance. Verify FEMA flood zone map.

ADA — New Orleans Accessible Design

2018 IBC Ch. 11 w/ LA amendments / ADA 2010
ada

IBC Chapter 11 with LA amendments. Accessible route, restroom. LA follows federal ADA. Flood-elevated buildings may need accessible ramp to BFE level.

Examiner Note: NOLA requires accessible path even to flood-elevated buildings. May need ramp design to meet both flood and ADA requirements.

Common rejection: Flood-elevated building not accessible; ramp to BFE not provided

Correction: Show accessible route including ramp to BFE level if elevated. Detail per IBC Ch. 11/ADA.

Egress — New Orleans Exit Requirements

2018 IBC §1006 / §1017 w/ LA amendments
egress

IBC egress with LA amendments. Two exits for 50+ occupants. Travel distance 250/300 feet. Exit signs on emergency power.

Examiner Note: NOLA follows IBC egress with LA amendments.

Common rejection: Occupant load not on plans; exit signs not on emergency power

Correction: Add occupant load on A-1. Show exit signs on emergency power. Dimension travel distance.