Tucson Planning & Development Services Department (PDSD)

Tucson, AZ

Avg Review

20d

Rejection Rate

35%

Skill Files

8

Status

Medium

Ventilation — Tucson Type I Hood

2018 IMC 507 / NFPA 96
ventilation

Type I hoods per IMC. Same codes as Phoenix/Mesa. Desert climate. Exhaust 400 CFM/LF. Makeup air 80-100%. Equipment rated for extreme heat.

Examiner Note: Tucson PDSD follows standard IMC. Desert climate considerations. Fast review.

Common rejection: Makeup air not shown; equipment not rated for heat

Correction: Show makeup air on roof plan rated for desert heat. Include exhaust CFM on M-1.

Fire Suppression — Tucson NFPA 96

NFPA 96 / UL 300 / Tucson Fire Code
fire

UL 300 suppression for Type I hoods. Tucson Fire reviews fire plans. Automatic gas shutoff.

Examiner Note: Tucson Fire reviews as part of PDSD permit. Include fire details in submittal.

Common rejection: UL 300 documents missing

Correction: Include UL 300 documents. Show suppression system on FP-1.

Plumbing — Tucson Grease Interceptor

2018 IPC / Tucson Water
plumbing

Grease interceptor per IPC. Tucson Water reviews FOG. 3-comp sink. Water conservation critical — Tucson has strict water use requirements.

Examiner Note: Tucson Water has FOG and water conservation programs. Submit interceptor details. Specify water-efficient fixtures.

Common rejection: Water conservation fixtures not specified; interceptor not submitted to Tucson Water

Correction: Submit interceptor to Tucson Water. Specify water conservation fixtures on P-1 per Tucson requirements.

Electrical — Tucson Kitchen Circuits

2017 NEC
electrical

Standard NEC. GFCI within 6 feet of water. Emergency disconnect. AZ follows NEC with minimal amendments.

Examiner Note: Tucson follows standard NEC. Fast review.

Common rejection: GFCI not shown

Correction: Add GFCI within 6 feet of water on E-1. Show emergency disconnect.

Health — Tucson Food Facility

ARS §36-1761 / Pima County Health Dept
health

Pima County Health Department reviews food facility plans. Handwash, 3-comp sink, FRP, sealed floors. Separate health permit.

Examiner Note: Pima County Health requires plan review. Standard food facility review process.

Common rejection: Health review not submitted; kitchen finishes incomplete

Correction: Submit food facility plan to Pima County Health. Specify finishes on A-series sheets.

Structural — Tucson Loads

2018 IBC §1607 / ASCE 7-16
structural

Seismic Design Category B. Low seismic. No snow. Equipment anchorage. AZ PE required.

Examiner Note: Tucson follows standard IBC structural. AZ PE stamp required.

Common rejection: AZ PE stamp missing

Correction: Provide AZ PE-stamped calculations. Show equipment anchorage on S-1.

ADA — Tucson Accessible Design

2018 IBC Ch. 11 / ADA 2010
ada

Standard IBC/ADA accessibility. Accessible route, restroom.

Examiner Note: Tucson follows standard IBC/ADA.

Common rejection: Accessible route not dimensioned

Correction: Show accessible route on A-1. Detail restroom per IBC Ch. 11.

Egress — Tucson Exit Requirements

2018 IBC §1006 / §1017
egress

Standard IBC egress. Two exits for 50+ occupants. Travel distance 250/300 feet.

Examiner Note: Tucson follows standard IBC egress.

Common rejection: Occupant load not on plans

Correction: Add occupant load per IBC 1004 on A-1. Show travel distance.